Philips HeartStart FRx Features
- Preconnected SMART Pads II can be used for both adults and children.
- The device reduces the shock energy to a level more appropriate for an infant or a child.
- Intuitive, clean design and clear voice instructions, including CPR coaching.
- Wireless Data Transfer Infrared data port for easy transmission to a Smartphone or PC running Event Review software, without cables or hardwire compatibility issues.
- The Philips SMART Biphasic waveform is highly effective, yet minimizes harmful side effects.
Philips HeartStart FRx Specifications
Dimensions
- Height: 7.1″ ( 18cm)
- Depth: 2.4″ (6 cm)
- Width: 8.9″ (22 cm)
- Weight: With battery and pads case: 3.5 lbs. (1.5 kg)
Environmental / Physical Requirements
- Sealing: Waterjet proof IPX5 per IEC60529
- Dust protected IP5X perIEC60529
- Temperature: Operating/Standby: 32º – 122º F (0º- 50º C)
- Altitude: 0 to 15,000 feet
- Aircraft: Device: RTCA/DO-160D;1997
- Crush: 500 pounds
- Vibration Operating: meets MILSTD 810F Fig.514.5C-17, random;
- Standby: meets MILSTD 810F Fig.514.5C-18, swept sine
- EMI (radiated/ immunity): CISPR II Group I Class B, IEC 61000-4-3, and IEC 61000-4-8
Battery (m5070A)
- Aviation: 989803139301 (TSO C-142-U.S. only)
- Type: 9 Volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life primary cell
- Capacity: Minimum 200 shocks or 4 hours of operating time (EN 60601-2-4:2003)
- Install-by date: Battery is labeled with an install-by date of at least 5 years from the date of manufacture
- Standby life: Four years typical when the battery is installed by the install-by date. (Will power the AED in standby state within the specified standby temperature range, assuming 1 battery insertion test and no defibrillation uses)
Smart Pad II
- Item number: 989803139261
- Active surface area: 12.4˝2 (80 cm2 ) each
- 13.2˝2 (85 cm2 ) each
- Cable length: 48˝ (121.9 cm)
- Use-by date: Pads case is labeled with a use-by date of at least 2 years from date of manufacture
- Infant/Child Key: Item # 989803139311
Defibrilator
- Defibrillator family Order 861304. Defibrillator, battery, SMART Pads II (1 set), Setup and Maintenance Guides, Owners Manual, Quick Reference Guide, Date sticker
- HeartStart FRx Ready-Pack configuration: Order Option R01. Defibrillator, battery, carry case, SMART Pads II (1 pre-connected set, 1 spare set), Setup and Maintenance Guides, Owners Manual, Quick Reference Guide, Date Sticker
- Waveform :Truncated Exponential Biphasic. Waveform parameters adjusted as a function of each patient’s impedance
- Therapy Adult defibrillation: Peak current 32A (150 J nominal into a 50-ohm load). Pediatric defibrillation with optional FRx Infant/Child key installed: Peak current 19A (50 J nominal into 50-ohm load)
- Protocol Device follows preconfigured settings. Defibrillation and CPR protocol can be customized using HeartStart Event Review software
User Interface
- Instructions: Detailed voice prompts and visual icons guide responder through use of the defibrillator
- CPR coaching: Voice coaching for adult and infant/child CPR provides instructions and audio cues for the appropriate number, rate and depth of chest compressions, as well as for each breath
- Controls: Green On/Off button, blue i-button, orange Shock button, optional Infant/Child key
- Indicators: Ready light, blue i-button, caution light, illuminated pads, icons, Shock button lights up when shock is advised
Date Recording and Transmission
- Infrared : Wireless transmission of event data to a Smartphone or PC, using the IrDA protocol
- HeartStart Event Review Data management software (optional) for download and review of Software: data retrieved through defibrillator’s infrared data port
- Data stored: First 15 minutes of ECG and the entire incident’s events and analysis decisions