Criticare Poet IQ 8500H Features
- Integrated CO2/agent detector.
- Measures carbon dioxide, nitrous oxide, and five halogenated anesthetic agents.
- Uses proprietary High IQ technology to identify and quantify agent gases.
- No moving parts.
- Reduced size.
- Reliable.
Criticare Poet IQ 8500H Specifications
Dimensions
- Height: 4.2” (10.7 cm)
- Width: 13.75” (34.9 cm)
- Depth: 10.75” (27.3 cm)
- Weight: 7.5 lbs (3.4 kg)
Pneumatics
- Flow rate: 100, 150, 200 ml/min, User Selectable
- Occlusion Clearing: Automatic
- Filters: WaterChek 2+
- Sample Lines: Cat. No. 625N, 8 foot
- Pneumatic Sound Pressure: 45 dBa maximum @ 1 meter
Communications
- Communication: Async Serial (RX/TX); CANBUS
- IBench Data Port: DB-9 connector
- Charger Port: 12.0VDC nominal, 1.0 Amp nominal
Capnometry (CO2)
- Method: Sidestream; non-dispersive infrared
- Range: 0-99 mmHg, 0 to 12.5%, 0 to 12.5 kPa, 0 to 99 Torr
- Resolution: 1 mmHg, 0.1%, 0.1 kPa, 1 Torr
- Accuracy: ±0.2% abs. or 4% of reading for breath rates up to 60 breaths/minute
- Flow Rate: 100, 150, 200 ml/min, user selectable
- Flow Tolerance: ±10%
- Rise Time: (10-90%) 350 milliseconds @ 150 ml/min
- Response Time: 2.25 seconds
- Time from Cold Stat: 1 minute to first waveforms; <20 minutes to full accuracy
- Calibration: Auto-calibrating, Manual Calibration
- Units: mmHg; Volume Percent; kPa; Torr
- Display: Inspired CO2, Expired CO2 (End-Tidal) Numerical values, capnograph, and breath by breath EtCO2 bar graph.
CO2 Respiration
- Source: Capnogram
- Range: 1 to 100 breaths/minute
- Resolution: 1 breath/minute
- Accuracy: ± 2 breaths/minute or 2% of reading
Nitrous Oxide (N2O)
- Method: Sidestream; non-dispersive infrared
- Range: 0 to 99 volume percent
- Resolution: 1%
- Accuracy: ± (1.5% abs. + 4% of reading) for breath rates up to 60 breaths/minute
- Identification Threshold: 5% (for single and mixed agents)
- Rise Time: (10-90%) 400 milliseconds
- Response Time: 2.5 seconds
- Calibration: Auto-calibrating, Manual Calibration
- Units: Percent
- Display: Numerical Inspired N2O, Expired N2O; N2O waveform
Oxygen Monitoring (O2)
- Units: Percent
- Display: Inspired O2, Expired O2, Numerical values, waveform
- Method: Oxidation-reduction galvanic cell
- Range: 0-100%
- Resolution: 1%
- Accuracy: ± 3 vol. % (0 – 90%) ± 4 vol. % (91- 100%) for breath rates up to 60 breaths/minute
- Rise Time: (0-90%) 600 milliseconds
- Response Time: 1.5 seconds
Halogenated Agents
- Method: Sidestream; non-dispersive infrared
- Units: Volume Percent
- Resolution: 0.1 Volume Percent
- Range
- Halothane; 0 to 10.0 vol. %
- Isoflurane; 0 to 10.0 vol. %
- Enflurane; 0 to 10.0 vol. %
- Desflurane; 0 to 20.0 vol. %
- Sevoflurane; 0 to 10.0 vol. %
- Accuracy: ± (0.1% abs. + 4% of reading) for breath rates up to 60 breaths/minute
- Identification Threshold
- Halothane; 0.2 vol. %
- Isoflurane; 0.3 vol. %
- Enflurane; 0.3 vol. %
- Desflurane; 0.3 vol. %
- Sevoflurane; 0.3 vol. %
- Mixed Gas Threshold: 0.2 vol. % + 10% of total concentration