Axia V1500A Patient Monitor Features
- 15-Inch touchscreen display.
- Manage up to 72 hours of detailed patient data.
- Easily upgradable from a basic vital signs monitor to a continuous bedside monitor, to an operating room monitor while keeping the patient on a single monitor at all times.
- Offers Ethernet and RS-232 connections with open source communication protocol.
- HL7 compliant.
Axia V1500A Patient Monitor Specifications
Applications
- Neonatal
- Pediatric
- Adult patients
- Anesthetic measurement
General
- Display: 15-inch color touchscreen
- Trace: 8 waveforms
- Indicator: Alarm indicator, Power indicator, QRS beep and alarm sound
- Trend time: 1 – 72 hour
Recorder
- Type: Built-in, thermal array, 3 channels
- Record width: 48mm
- Recorder paper: 50mm
- Record speed: 25mm/s, 50mm/s
Networking
- Industry standard 802.11b/g wireless network
Power
- Source: External AC power or internal battery
- AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
- Battery: Built-in & rechargeable lithium ion
- Operating Time: 3+ hours
Environmental
- Operating Temperature: 5 ~ 40 °C
- Storage Temperature: -20 ~ 65 °C
- Operating Humidity: ≤80%
- Storage Humidity: ≤80%
ECG
- Input: 5-lead ECG cable and standard AAMI line for connection
- Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
- Gain Choice : x0.5, x1, x2, x4
- Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
- ECG Waveforms: 7 channels
- Penetration Voltage: 4000VAC 50/60Hz
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
- HR Display Range: 30 ~ 300bpm
- Accuracy: ±1bpm or ±1%, whichever is greater
- Alarm Limit Range Setting: Upper limit 10
RESP
- Measure Method: RA-LL impedance
- Range: 0 ~ 120 rpm
- Accuracy: ±3 rpm
- Alarm Limit Setting: Upper limit 6 ~ 120 rpm,; lower limit 3 ~ 120 rpm
- Sweep Speed:12.5, 25, 50 and 100 mm/sec (left to right or right to left)
SpO2
- ASpO2: Anti-motion SpO2
- SpO2% Range: 0-100%
- SpO2 Accuracy: ±2% (70 ~ 100%, non-motion); ±3% (70 ~ 100%, motion)
- Pulse Rate Range: 30-250 bpm
- Pulse Rate Accuracy: ±2 bpm (non-motion; ±3 bpm (motion)
- Alarm Limit Setting: Upper limit 70 ~ 100%,; lower limit 70 ~ 100%
- SpO2 Probe: Red light LED wavelength 660nm±5nm; Infrared light LED wavelength 940nm±10nm
NIBP
- Measuring Technology: Automatic oscillating measurement
- Cuff Inflating: <30s (0 ~ 300 mmHg, standard adult cuff)
- Measuring Period: AVE<40s
- Mode: Manual, Auto
- Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
- Pulse Rate Range: 30 ~ 250 (bpm)
- Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg); DIA: 15 ~ 200 (mmHg)
- Neonatal Mode: SYS: 40 ~ 135 (mmHg); DIA: 15 ~ 100 (mmHg)
- Maximum Mean error: ±5mmHg
- Maximum Standard deviation: 8mmHg
- Resolution: 1mmHg
- Overpressure Protection: Adult Mode: 300 (mmHg); Neonatal Mode: 160 (mmHg)
- Alarm Limit Setting: SYS: 50 ~ 240 mmHg
- DIA: 15 ~ 180 mmHg
TEMP
- Range: 25 ~ 50 (°C)
- Accuracy: ± 0.2°C (25.0 ~ 34.9°C); ± 0.1°C (35.0 ~ 39.9°C); ± 0.2°C (40.0 ~ 44.9°C); ± 0.3°C (45.0 ~ 50.0°C)
- Display Resolution: 0.1°C
- Alarm Limit Setting: Upper limit 0 ~ 50°C, lower limit 0 ~ 50°C
- Channel: 2 channels
IBP
- Measurement Range: -50 ~ 300mmHg
- Channel: 2 channels
- Pressure Transducer: Sensitivity, 5μV/V/mmHg
- Impedance Range: 300 ~ 3000Ω
- Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
- Unit: mmHg/kPa selectable
- Resolution: 1mmHg
- Accurancy: ±1mmHg or ±2%, whichever is greater
- AlarmRange: -10 ~ 300mmHg
EtCO2
- CO2 Measurement Range: 0 ~ 99mmHg
- Accuracy: ±2mmHg (0 ~ 38mmHg); 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)
- Sampling Rate: 50 ml/min
- Initialization Time: 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes
- Respiration Rate: 0 ~ 150 breaths
- Mode: Adult, neonate
C.O. (Cardiac Output)
- Measurement Method: Thermodilution Method
- Measurement Range
- C.O.: 0.1 to 20 L/min
- TB: 23 to 43℃
- TI: 0 to 27℃
- Resolution
- C.O.: 0.1 L/min
- TB, TI 0.1℃
- Accuracy
- C.O. ±5% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves.
- TB, TI: ±0.1(without sensor)
- Alarm Range: TB 23 to 43℃
- Repeatability: C.O. ±2% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves
Anesthetic Agents
- Method:Infrared absorption
- Gas Sorts: Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, O2 (optional Automatic Agent ID)
- Measurement Range
- Halothane, Isoflurane: 0 ~ 8.5%
- Enflurane, Sevoflurane: 0 ~ 10%
- Desflurane: 0 ~ 20%
- CO2: 0 ~ 10%
- N2O: 0 ~ 100%
- O2: 0 ~ 100%
- Bias
- Halothane, Isoflurane, Enflurane, Sevoflu rane, Desflurane: ±(0.15 Vol% + 15% rel.)
- CO2: ±(0.5 Vol% + 12% rel.)
- N2O: ± (2 Vol% + 8% rel.)
- O2: ±3 Vol%
Other Standard Features
- OxyCRG
- Drug dose calculation
- Cascading ECG
- On screen NIPB trends (up to 250 readings)
- User set defaults
- Arrhythmia detection
- ST segment