Axia V1500A Touchscreen

The Axia V1500A patient monitor is designed for a fast-paced work environment. It offers standard measurements of NIBP, ECG, SpO2, Temperature, and Respiration. End-tidal CO2, Anesthetic Agent Measurement, Cardiac Output, and Invasive Blood Pressure can be added on-site by attaching plug-in modules. The V1500A has a 15-Inch high-resolution touchscreen monitor to optimize the speed of patient care.

Worldwide Sales & Service

  • Upto 50% Below OEM pricing
  • Reliable Equipment’s for your Facility

Axia V1500A Patient Monitor Features

  • 15-Inch touchscreen display.
  • Manage up to 72 hours of detailed patient data.
  • Easily upgradable from a basic vital signs monitor to a continuous bedside monitor, to an operating room monitor while keeping the patient on a single monitor at all times.
  • Offers Ethernet and RS-232 connections with open source communication protocol.
  • HL7 compliant.

Axia V1500A Patient Monitor Specifications

Applications

  • Neonatal
  • Pediatric
  • Adult patients
  • Anesthetic measurement

General

  • Display: 15-inch color touchscreen
  • Trace: 8 waveforms
  • Indicator: Alarm indicator, Power indicator, QRS beep and alarm sound
  • Trend time: 1 – 72 hour

Recorder

  • Type: Built-in, thermal array, 3 channels
  • Record width: 48mm
  • Recorder paper: 50mm
  • Record speed: 25mm/s, 50mm/s

Networking

  • Industry standard 802.11b/g wireless network

Power

  • Source: External AC power or internal battery
  • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery: Built-in & rechargeable lithium ion
  • Operating Time: 3+ hours

Environmental

  • Operating Temperature: 5 ~ 40 °C
  • Storage Temperature: -20 ~ 65 °C
  • Operating Humidity: ≤80%
  • Storage Humidity: ≤80%

ECG

  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice : x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range: 30 ~ 300bpm
  • Accuracy: ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting: Upper limit 10

RESP

  • Measure Method: RA-LL impedance
  • Range: 0 ~ 120 rpm
  • Accuracy: ±3 rpm
  • Alarm Limit Setting: Upper limit 6 ~ 120 rpm,; lower limit 3 ~ 120 rpm
  • Sweep Speed:12.5, 25, 50 and 100 mm/sec (left to right or right to left)

SpO2

  • ASpO2: Anti-motion SpO2
  • SpO2% Range: 0-100%
  • SpO2 Accuracy: ±2% (70 ~ 100%, non-motion); ±3% (70 ~ 100%, motion)
  • Pulse Rate Range: 30-250 bpm
  • Pulse Rate Accuracy: ±2 bpm (non-motion; ±3 bpm (motion)
  • Alarm Limit Setting: Upper limit 70 ~ 100%,; lower limit 70 ~ 100%
  • SpO2 Probe: Red light LED wavelength 660nm±5nm; Infrared light LED wavelength 940nm±10nm

NIBP

  • Measuring Technology: Automatic oscillating measurement
  • Cuff Inflating: <30s (0 ~ 300 mmHg, standard adult cuff)
  • Measuring Period: AVE<40s
  • Mode: Manual, Auto
  • Measuring Interval in AUTO Mode: 2 min ~ 4 hrs
  • Pulse Rate Range: 30 ~ 250 (bpm)
  • Adult/Pediatric Mode: SYS: 40 ~ 250 (mmHg); DIA: 15 ~ 200 (mmHg)
  • Neonatal Mode: SYS: 40 ~ 135 (mmHg); DIA: 15 ~ 100 (mmHg)
  • Maximum Mean error: ±5mmHg
  • Maximum Standard deviation: 8mmHg
  • Resolution: 1mmHg
  • Overpressure Protection: Adult Mode: 300 (mmHg); Neonatal Mode: 160 (mmHg)
  • Alarm Limit Setting: SYS: 50 ~ 240 mmHg
  • DIA: 15 ~ 180 mmHg

TEMP

  • Range: 25 ~ 50 (°C)
  • Accuracy: ± 0.2°C (25.0 ~ 34.9°C); ± 0.1°C (35.0 ~ 39.9°C); ± 0.2°C (40.0 ~ 44.9°C); ± 0.3°C (45.0 ~ 50.0°C)
  • Display Resolution: 0.1°C
  • Alarm Limit Setting: Upper limit 0 ~ 50°C, lower limit 0 ~ 50°C
  • Channel: 2 channels

IBP

  • Measurement Range: -50 ~ 300mmHg
  • Channel: 2 channels
  • Pressure Transducer: Sensitivity, 5μV/V/mmHg
  • Impedance Range: 300 ~ 3000Ω
  • Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
  • Unit: mmHg/kPa selectable
  • Resolution: 1mmHg
  • Accurancy: ±1mmHg or ±2%, whichever is greater
  • AlarmRange: -10 ~ 300mmHg

EtCO2

  • CO2 Measurement Range: 0 ~ 99mmHg
  • Accuracy: ±2mmHg (0 ~ 38mmHg); 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)
  • Sampling Rate: 50 ml/min
  • Initialization Time: 30 seconds (typical), reaches ±5% steady-state accuracy within 3 minutes
  • Respiration Rate: 0 ~ 150 breaths
  • Mode: Adult, neonate

C.O. (Cardiac Output)

  • Measurement Method: Thermodilution Method
  • Measurement Range
    • C.O.: 0.1 to 20 L/min
    • TB: 23 to 43℃
    • TI: 0 to 27℃
  • Resolution
    • C.O.: 0.1 L/min
    • TB, TI 0.1℃
  • Accuracy
    • C.O. ±5% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves.
    • TB, TI: ±0.1(without sensor)
  • Alarm Range: TB 23 to 43℃
  • Repeatability: C.O. ±2% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves

Anesthetic Agents

  • Method:Infrared absorption
  • Gas Sorts: Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, O2 (optional Automatic Agent ID)
  • Measurement Range
    • Halothane, Isoflurane: 0 ~ 8.5%
    • Enflurane, Sevoflurane: 0 ~ 10%
    • Desflurane: 0 ~ 20%
    • CO2: 0 ~ 10%
    • N2O: 0 ~ 100%
    • O2: 0 ~ 100%
  • Bias
    • Halothane, Isoflurane, Enflurane, Sevoflu rane, Desflurane: ±(0.15 Vol% + 15% rel.)
    • CO2: ±(0.5 Vol% + 12% rel.)
    • N2O: ± (2 Vol% + 8% rel.)
    • O2: ±3 Vol%

Other Standard Features

  • OxyCRG
  • Drug dose calculation
  • Cascading ECG
  • On screen NIPB trends (up to 250 readings)
  • User set defaults
  • Arrhythmia detection
  • ST segment

Additional information

Manufacturer

Axia